INSTALLATION:

  1. Press INCON ICS Standard female coupler on the steel bar using INCON swaging machine.
  2. Place the threaded rod of the bar terminator on the coupler’s end and rotate it until it is completely secured.

CONFIGURATION:

INCON ICTB – Bar Terminator is composed of a male end anchor compatible with a corresponding INCON ICS – Standard female coupler sleeve.

MAIN APPLICATION:

INCON ICTF – Bar Terminator is used in lieu of hooked or bent bars to provide the required anchorage and development length of the embedded steel bars.

Features:

Applicable for high strength reinforcing bars up to ASTM Grade 75.
Satisfies the requirements of ACI 318, BS 8110, UBC 1997, NF 35-20-1 and DIN 1045.
Easily installed and highly efficient for achieving the required anchorage strength of steel bars.
Highly reliable and consistent performance due to our swaging technology and enhanced terminator design.
Compact design of the bar terminator to reduce reinforcement congestion at the connections.
Enhances anchorage performance compared to hooked or bent bars especially for large bar diameters.

AVAILABLE MATERIALS AND COATINGS:

Uncoated steel bar terminators for providing anchorage of bars in typical construction applications.
Zinc coated steel bar terminators for providing anchorage of steel bars in corrosive environments and for other special applications.
Stainless steel bar terminators for providing anchorage of  stainless steel bars and for other special applications.
Galvanized steel bar terminators for providing anchorage of galvanized steel bars and for other special applications.